Add insulation to attic.
Attic insulation r value zone 4.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
To choose the best insulation for your home from the many types of insulation on the market you ll need to know where you want or need to install the insulation and what r value you want the installation to achieve.
First things first you need to go up into your attic inspect the condition of the insulation and calculate the current level of insulation.
For over 50 years insulfoam has been enabling building professionals to construct high quality building insulation systems at a minimal cost.
Compare insulation r values before you buy.
Csl and is the nation s largest manufacturer of block molded expanded polystyrene eps.
Insulfoam is a division of carlisle construction materials a wholly owned subsidiary of carlisle companies nyse.
These r values are a sum meaning this should be the total r value once you add up the entire depth of insulation.
The higher the r value the greater the insulating power.
Whenever exterior siding is removed on an uninsulated wood frame wall.
This chart shows the r value of this insulation.
In comparison an inch of blown fiberglass insulation has an r value of 3 1 3 4 and an inch of blown cellulose in an attic has an r value of 3 2 3 7.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
The higher r value the better insulation performance.
The amount and r value of your attic floor insulation depends on your geographical location zone.
Recommended home insulation r values.
The table below shows what levels of insulation are cost effective for different climates and.
Zone uninsulated attic existing 3 4 of insulation.
The r value or r value is a measure of thermal resistance ability to resit heat traveling through it used in the building and construction industry.
The higher the r value the better the thermal performance of the insulation.
Other considerations may include indoor air quality impacts life cycle costs recycled content embodied energy and ease of installation especially if you plan to do the.
Along with knowing the r value of a particular insulation it is also important to calculate the r value of a total system.
Inspecting your attic insulation.
Insulation level are specified by r value.
R value is a measure of insulation s ability to resist heat traveling through it.
Department of energy recommended r values for add insulation to attic zone 4 uninsulated attic attic insulation run between r 49 to r 60 existing attic 3 4 inches of insulation r 38 walls should be between r 19 to r 21 basement walls r13 to r 19 floors r 25 to r 30.
For example if you have a type of insulation that has an r value of r 5 per inch of thickness you will need a depth of 6 inches of this insulation installed in your attic to reach r 30 if you live in zones 2 or 3.