Baby changing stations should meet the requirements of the ada.
Baby changing station height ada.
306 3 knee clearance knee clearance shall extend 25 inches 635 mm maximum under an element at 9 inches 230 mm above the finish floor or ground.
This baby changing station has been tested to support 200 lbs with minimal deflection.
Side reach like forward reach requirements side reach compliance calls for a high side reach of 48 inches and a low side reach of 15 inches.
Baby changing stations.
Any change to restroom functionality inevitably turns to the question of americans with disabilities act ada compliance.
There are specific mounting heights and other requirements of baby changing stations in restrooms says ada compliance expert joan stein of stein consulting inc pittsburgh.
Below is a diagram from diaper depot about mounting baby changing stations.
Recess mounted plastic baby changing station with stainless steel flange is a stylish and safe option for restroom facilities.
The americans with disabilities act ada was created to ensure access to buildings and structures for people with disabilities.
Check your local code for addition information and requirements.
Oval baby changing stations.
Information and figures are taken directly from the 2010 ada standards for accessible design regulation www ada gov and can be freely viewed or downloaded at your convenience.
Install at the perfect height.
This product is designed for infants only up to 3 5 years of age and weighing less than 50 lbs.
8365328 8276229 d605886 d601843 canadian patent no.
Baby changing stations types.
130179 european community 1114367 0001 1114367 0002 australia patent no.
Complete the design by providing the required amount of toe clearance underneath the lavatory of 17 inches 430mm to 25 inches 635mm maximum.
The ada mandates that baby changing stations be present in both men s and women s restrooms and must be placed at a height of 27 inches from the floor.
Horizontal stainless steel recess mounted kb110 ssre.
Recess mounted stainless steel clad baby changing station is the premier choice for upscale restroom facilities.
Ada regulations also state that baby changing stations must be located in an area that is easily accessible and free from obstructions.
Forward reach a unit should not require a high forward reach no more than 48 inches and a low reach of 15 inches above the finish floor or ground when unobstructed.
This is required so patrons using wheelchairs can easily access the unit as well as open and close the changing station.
They have to be mounted so that the very top of the changing table surface when it is opened cannot be any higher than 34 inches off the floor she says.
The ada standards are issued by the department of justice doj and the department of transportation dot.
Toe clearance at least 9 inches 230mm above the finish floor must be provided for the full depth.